Office air conditioning in Leamington Spa

Is your Leamington Spa office or studio unbearable by mid-afternoon? We fit air conditioning for workplaces of all sizes, including the game studios this town is known for. We size it for the people and machines in the room, plan the work around your hours and leave you with a floor your team can work on.

Get an office quote

Name, number, postcode. We call you back to talk it through.

Enquiries are shared only with the team who quotes for and does the work. Your details are used to deal with this request only (privacy notice).

  • Sized for people and machines
  • Work planned around your hours
  • Help with TM44 thresholds

Why do Leamington studios run so hot?

Because of what is in them. In 2021 the town's MP told Parliament that the Silicon Spa cluster employed over 2,000 people in 32 studios. Each desk in a games business may have a powerful PC and several screens, all of it turning into heat. Server Room Environments puts it simply: a 900W machine gives out 900W of heat. Add a person, which the same guide counts at 400 BTU, and a small room quickly needs real cooling, even in spring. Sources: Parallel Parliament; Server Room Environments.

What does the law ask of an employer?

Indoor workplaces must be kept at a reasonable temperature during working hours, under regulation 7 of the 1992 Workplace Regulations. GOV.UK says there is no guidance for a maximum limit, and suggests a minimum of 16°C, or 13°C for physical work. The Health and Safety Executive treats heat as a hazard to be assessed like any other, and its 2026 statements told employers to act during heat alerts. Sources: legislation.gov.uk; GOV.UK; HSE.

How do we work out what an office needs?

  • Floor area, ceiling height and how much glass faces the sun.
  • How many people work there at the busiest time.
  • Wattage of the computers, screens and lighting.
  • Any server cupboard, which usually needs its own cooling.
  • Who controls the building, and what the lease says about plant.

Offices in converted Regency buildings add height limits, listed status and a shared stair to think about, so we look at the access early.

Do you need planning permission for an office unit?

Most likely. The Planning Portal says air source heat pumps on non-domestic land are likely to need an application, and the home rules do not cover workplaces. In the Royal Leamington Spa conservation area, a visible position will take particular thought, so we usually start at the rear or on an existing flat roof. Your landlord will need to agree too. Sources: Planning Portal; Warwick District Council.

What is a TM44 inspection, and do you need one?

If the air conditioning units you control add up to more than 12kW, an energy assessor has to inspect the system, with no more than five years between visits. Small units count towards the total. Whoever controls the system arranges this and keeps the report. Having no report can bring a £300 fixed penalty from Trading Standards, and not handing it over within a week of being asked can bring £200. Source: GOV.UK.

Common questions

Can you work outside office hours?

We plan noisy work around your team wherever we can. Tell us your hours and any release dates at the survey, and we will build the plan around them.

We lease our office. Who pays and who decides?

That depends on the lease. Your landlord will almost certainly need to agree to plant on the building, so ask early and send us any contractor rules.

What should the office thermostat be set to?

The law does not fix a figure. Agree one with your team. There is no point running the system colder than people actually want.

Sources

Before you ring

These details let us give you a better answer on the first call.

  • Your postcode
  • Flat, house or workplace
  • Whether the building is listed
  • Which rooms, roughly how big, and which way they face
  • Who owns the outside walls, if you lease or rent